Scorpion 114

Single-use hollow-carrier perforating system for deployment on wireline, coiled tubing, or tubing.

Characteristics of the Scorpion 114 perforating system
Parameter Value
Outer diameter, mm

  -  without installed centralizers  114  
  -  with installed centralizers  138   
Minimum casing drift diameter, mm

  -  without installed centralizers   143  
  - with installed centralizers   148  
Maximum allowable operating temperature, when held for 1 hour, °C   (170-200)±51)    
Maximum allowable hydrostatic pressure, MPa  80-1402)    
Maximum carrier diameter after perforator firing, mm:  
in a liquid environment 120
in a gas environment 120
Perforator section length, m 1/2/3/4/5/6
Specific mass of a loaded section, kg/rm3) 40.5
Maximum wellbore dogleg severity, deg/10 m:  
for a multi-section perforator of standard design 5.0
for a multi-section perforator using articulated joint assemblies (SHUS or SHUS-A): for sections 1/2/3/4 m long 21.5/12.5/6.5/5.0
Phase orientation of standard perforator charges, deg.4) 60

1) The maximum allowable operating temperature and holding time of the loaded perforator are determined by the operational documentation for the EM (explosive materials) having the lowest allowable application temperature compared to the other EMs included in the explosive train of the perforator, as well as by the characteristics of the rubber products used.

2) The maximum allowable pressure may vary depending on the mechanical properties of the carrier tubes.

3) Mass of a running meter of a fully loaded section excluding the mass of reusable elements.

4) Phasing can be changed by special order.   
Characteristics of the applied charges
Shaped charge name Charge type Total explosive mass in the charge, g1) Perforation density, shots/m/phasing, deg.
Average parameters of charge penetration performance, mm   
 Indicators on a QC-type composite target    Indicators according to API 19B
Penetration depth  Entrance hole diameter  Penetration depth  Entrance hole diameter 
Scorpion PP-32DP DP 25.3-31.8 20, 18, 16, 13, 10/
60
1100 11 - -
Scorpion PP-32SDP  SDP     29.3-31.8 1300 10 - -
Scorpion PP-32SBH  SBH 24.3-26.8 210 25 - -
Scorpion PP-36SDP SDP 37.3-41.3 16, 13, 10/
60
1600 12 1603 10.88
Scorpion PP-36GH  GH 35.3-37.8 1100 15 - -

1) Depending on the explosive material used in the charge.

Phasing and layout
CONTACT US

We are always available and ready to answer your questions

Submit a request

Fill out the form and we will contact you within one business day